The OpenNET Project / Index page

[ новости /+++ | форум | wiki | теги | ]

Интерактивная система просмотра системных руководств (man-ов)

 ТемаНаборКатегория 
 
 [Cписок руководств | Печать]

tavor (7)
  • >> tavor (7) ( Solaris man: Макропакеты и соглашения )
  •  

    NAME

    tavor - InfiniHost MT23108/MT25208 InfiniBand (IB) Driver
     
    

    SYNOPSIS

    PCI   pci15b3,5a44@pci-slot, pci15b3,5a45@pci-slot
    

    PCI-E pci15b3,6278@pci-e-slot, pci15b3,6279@pci-e-slot
    
     

    DESCRIPTION

    The tavor driver is an IB Architecture-compliant implementation of an HCA, which operates on the Mellanox MT23108 InfiniBand ASSP and the Mellanox MT25208 InfiniBand ASSP. These ASSP's support the link and physical layers of the InfiniBand specification, while the ASSP and the driver support the transport layer.

    The tavor driver interfaces with the InfiniBand Transport Framework (IBTF) and provides an implementation of the Channel Interfaces that are defined by that framework. It also enables management applications and agents to access the IB fabric.  

    FILES

    /kernel/drv/tavor

    32-bit ELF kernel module (x86 platform only).

    /kernel/drv/amd64/tavor

    64-bit ELF kernel module (x86 platform only).

    /kernel/drv/sparcv9/tavor

    64-bit ELF Kernel Module (SPARC platform only).

    /kernel/drv/tavor.conf

    Driver configuration file.

     

    ATTRIBUTES

    See attributes(5) for descriptions of the following attributes:

    ATTRIBUTE TYPEATTRIBUTE VALUE
    ArchitecturePCI-based systems
    AvailabilitySUNWtavor

     

    SEE ALSO

    driver.conf(4), printers.conf(4), attributes(5)

    Writing Device Drivers  

    DIAGNOSTICS

    In addition to being logged, the following messages may appear on the system console.

    tavor : driver attached for maintenance mode only.

    There was a failure in the boot process of the tavor ASSP and the only function that can be performed is to re-flash firmware on the ASSP.

    driver failed to attach.

    The ASSP could not boot into either operational (HCA) mode or into maintenance mode. The device in inoperable.

    Unexpected port number in port state change event.

    A port state change event occurred, but the port number in the message does not exist on this HCA. This message also indicates the port number that was in the port state change.

    Tavor driver successfully detached.

    The driver has been removed from the system, and the HCA is no longer available for transfer operations.

    tavor"n": port "m" up.

    A port up asynchronous event has occured. "n" represents the instance of the Tavor device number, and "m" represents the port number on the Tavor device.

    tavor"n": port "m" down.

    A port down aynchronous event has occurred.

    Tavor: <command name> command failed.

    A internal firmware command failed to execute.


     